EasyManua.ls Logo

AGFA PCR II Plus - Code 83: Illegal Command Byte; Code 84: Illegal Data Byte

AGFA PCR II Plus
167 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Code 83: Illegal Command Byte
Secondary Code: OO, Ol
While the film recorder was in the idle state, it received an unrecog-
nized command. The illegal command byte is contained in register H.
Secondary Code: 02
The film recorder received a command with an illegal parameter. The
command byte is contained in register H, and the illegal parameter is
contained in register L.
Code 84: Illegal Data Byte
Secondary Code: Ol
The film recorder received an illegal run-length code (a length of zero).
This code is contained in register E and indicates a special function.
The function code (INTENSITY) does not correspond to any of the al-
lowed codes. Function codes are contained in register C.
Secondary Codes: O2, O3, 04
02 indicates that the initial horizontal address was less than the al-
lowed minimum.
03 indicates that the calculated end address was greater than the al-
lowed maximum.
04 indicates that the calculated end address was less than the start
address.
For all three errors:
H and L contain the horizontal start address
D and E contain the end address
B and C contain the pixel count
A-14 PCR II Plus User Guide

Table of Contents