EasyManuals Logo

Alcatel-Lucent 7210 SAS Series User Manual

Alcatel-Lucent 7210 SAS Series
488 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #266 background imageLoading...
Page #266 background image
Basic Configurations
Page 260 7210 SAS D, E, K OS Quality of Service Guide
FCef = 0 + 0 + 0 + 0 = 0
FCh2 = 1 + 1 + 1 + 0 = 3
Since this FC uses unicast meter and broadcast meter, two entries are required to identify these
traffic types explicitly. Another entry is required to classify multicast and unknown-unicast traffic
type to the same FC and use the default meter #11.
FCl1 = 1 + 1 + 1 + 0 = 3
Since this FC uses only unicast meter, an entry is required to identify this traffic type explicitly.
Another entry is required to classify broadcast, multicast and unknown-unicast traffic type to the
same FC and use the default meter #11.
FCaf = 1 + 1 + 1 + 0 = 3
Since this FC uses unicast, broadcast and multicast meter, three entries are required to identify
these traffic types explicitly. Unknown-unicast traffic type is classified using the same entry as
multicast traffic type and uses the same meter.
FCl2 = 0 + 0 + 0 + 0 = 0
FCbe = 1 + 0 + 1 + 0 = 2
Using the above equation, the total classification entries used = 15 and the total meters used = 6.
If the same policy were to be used for a SAP in an Epipe service, then since all traffic is classified
to a unicast traffic type and since only unicast meters are used, the following are used:
FCnc = 0 + 0 + 0 + 0 = 0
FCh1 = 1 + 0 + 0 + 0 = 1
FCef = 0 + 0 + 0 + 0 = 0
FCh2 = 1 + 0 + 0 + 0 = 1
FCl1 = 1 + 0 + 0 + 0 = 1
FCaf = 1 + 0 + 0 + 0 = 1
FCl2 = 0 + 0 + 0 + 0 = 0
FCbe = 1 + 0 + 0 + 0 = 1
Using the above equation, the total classification entries used = 5 and the total meters used = 3
(since all FCs used only meter #1, meter #3 and meter #5).
Example 3a (Default multipoint meter "11" is not used) :
sap-ingress 10 create
description “example-policy-2
num-qos-classifiers 12
meter 1 create
rate cir 100 pir 100
exit
meter 3 create
rate cir 100 pir 100
exit
meter 2 create
rate cir 1 pir 20
exit

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent 7210 SAS Series and is the answer not in the manual?

Alcatel-Lucent 7210 SAS Series Specifications

General IconGeneral
BrandAlcatel-Lucent
Model7210 SAS Series
CategorySwitch
LanguageEnglish

Related product manuals