NTP 106 — Install a B-2404-P business ONT
NTP 106-4 November 2013 Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
Edition 01 3FE 55873 AAAA TCZZA
ONT Product Information Guide
Figure NTP 106-2: Wall mounting holes on B-2404-P business ONT fiber storage trays
iii If there is no wall mounting template, use the fiber storage tray as a
template to indicate the location of the mounting holes on the wall.
These holes should be the same distance apart as the distance between
the centers of the holes in the fiber storage tray.
iv Drill four holes in the wall where the ONT will be mounted and then
drive the mounting screws into the holes.
The recommended length of mounting screw is 1.15 inch (3.8 cm).
Do not drive the screw into the wall completely. Leave approximately
1/8 in. (6 mm) between the screw head and the wall surface.
v Wrap the optic cable around the spools in the fiber storage tray.
vi Attach the fiber storage tray to the ONT.
vii Slide the wall mount keyholes on the ONT enclosure or fiber storage tray
down over the mounting screws until the ONT is securely seated.
6 Connect up to two POTS cables to the RJ-11 ports (DLP 123).
7 Connect up to four Ethernet cables to the RJ-45 ports (DLP 101).
8 Connect up to four E1/T1 cables to the RJ-48C ports (DLP 104).
9 Connect the SC/APC adaptor to the fiber optic port (DLP 125).
Warning — Be careful to maintain a bend radius of no less than 1.5
inches (3.8 cm) when connecting the fiber optic cable. Too small of a
bend radius in the cable can result in damage to the optic fiber.
Wall
mounting
keyhole
Wall
mounting
keyhole
Wall
mounting
keyhole
Wall
mounting
keyhole
20815