Configuring Ethernet OAM Configuring Ethernet OAM
OmniSwitch AOS Release 6 Network Configuration Guide September 2009 page 15-11
Configuring the Fault Alarm Time
The Fault Alarm time is the period of time during which one or more defects should be detected before the
Fault Alarm is issued. The ethoam fault-alarm-time command can be used to configure the timeout value
for the Fault Notification Generation Alarm Time.
To configure the Fault Alarm time, enter the ethoam fault-alarm-time command, followed by the
number of seconds.
For example, to configure the Fault Alarm time value as 10 seconds, you would enter:
-> ethoam fault-alarm-time 10 end-point 100 domain esd.alcatel-lucent.com asso-
ciation alcatel_sales
Configuring the Fault Reset Time
The Fault Reset time is the time interval in which Fault Alarm is re-enabled to process the faults. The
ethoam fault-reset-time command can be used to configure the timeout value for the Fault Notification
Generation Reset Time.
To configure the Fault Reset time, enter the ethoam fault-reset-time command, followed by the number
of seconds.
For example, to configure the Fault Reset time interval as 5 seconds, you would enter:
-> ethoam fault-reset-time 5 end-point 100 domain esd.alcatel-lucent.com associ-
ation alcatel_sales