Combo Port Application Example Configuring Ethernet Ports
page 1-30 OmniSwitch AOS Release 6 Network Configuration Guide September 2009
3 Verify that combo ports 1/23 and 1/24 are set to the default setting of preferred fiber (which will make
the SFP connectors 1/23 and 1/24 the primary connections while copper combo ports 1/23 and 1/24 will
only become active if the equivalent SFP connectors go down) with the show interfaces status command
as shown below:
-> show interfaces 1/21-24 status
DETECTED CONFIGURED
Slot/ AutoNego Speed Duplex Hybrid Speed Duplex Hybrid Trap
Port (Mbps) Type (Mbps) Mode LinkUpDown
-----+--------+------+------+------+--------+------+------+------
1/21 Enable - - - 100 Auto FC -
1/21 Enable - - - 1000 Full FC -
1/22 Enable - - - 100 Auto FC -
1/22 Enable - - - 1000 Full FC -
1/23 Enable - - - 1000 Full PF -
1/23 Enable - - - 100 Auto PF -
1/24 Enable - - - 1000 Full PF -
1/24 Enable - - - 100 Auto PF -
FF - ForcedFiber PF - PreferredFiber F - Fiber
FC - ForcedCopper PC - PreferredCopper C - Copper
In the output above combo ports 1/23 and 1/24 are set to preferred fiber. (To configure combo ports as
preferred fiber use the interfaces hybrid preferred-fiber command.)