Once a unit is removed from service, vacuum all air vents, including the front panel
grill.
Clean the exterior with a mild solution of detergent and water. Apply the solution onto
a soft cloth, not directly to the surface of the unit. To prevent damage to materials, do
not use aromatic hydrocarbons or chlorinated solvents for cleaning.
Check external connections for integrity of insulation, loose contacts, and proper
torque.
If there is any evidence of short-circuits or arcing, overheating, or corrosion, contact
the factory for recommended service.
5.3 Fuses
There are no user replaceable components in the power supply. Internal fuses are listed
in Table 51. Fuses are sized for fault isolation, and, an open fuse might indicate that a
circuit component has been damaged. Contact the factory for further assistance.
CAUTION!
To reduce the risk of fire or electrical shock, replace fuses only
with the same type and rating.
Assembly
Reference
Rating
Manufacturer
Part No.
Distribution PWA
F2, F3
5 A, 600V
Littelfuse KLK-5
Input EMI Filter PWA
F1, F2, F3
30 A, 600V
Littelfuse KLK-30
Table 51. Fuse Ratings

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ametek Sorensen Asterion AST Series and is the answer not in the manual?

Ametek Sorensen Asterion AST Series Specifications

General IconGeneral
BrandAmetek
ModelSorensen Asterion AST Series
CategoryPower Supply
LanguageEnglish

Related product manuals