Overview  DC Asterion Series 
2-12  M330460-01  Rev A 
2.9  DC output power connection 
 
Figure 2-6. DC Output Busbar 
Output Power of the DC-Asterion series is through bus bars (POS and NEG) and the 
size could vary depending on the voltage and power models.  For example, see Figure 
2-6 for 40V-60V models. Table 2-4 provides output power connection descriptions. 
Refer to Table 2-5 for input/output lug recommendations. 
1.7 kW to 5 kW, 40V-60V models 
Bus bars with holes for M8 bolts on each terminal (POS. and 
NEG.) 
Table 2-4. DC Output Power Connections 
 
P, PV, or PN series, or 
equivalent 
Standard stranded wire: LCA 
Series, or equivalent 
Flexible stranded wire: LCAX 
Series, or equivalent 
Note:
 Contact lug manufacturer for recommended crimping tool. 
Table 2-5.  Recommended Lugs 
2.10  Remote Sense 
The Remote Sense Connector , RVS, is located on the rear panel. Figure 2-7 shows 
the rear panel view of the connector, and Table 2-6 lists the connector type.