Overview DC Asterion Series
3-14 M330460-01 Rev A
Example 1: Creating a Current ramp using Software Trigger mode
Set the Curr to 10A
Set the To Curr to 30A
Set the Volt to 25V
Set the Time to 10s
Connect an appropriate load to the supply
Select the Trigger mode as SW (software)
Click on Initialize
Click on Trigger Ramp
Observe that Trigger Ramp button will change to Abort button
Observe the current ramp signal using oscilloscope
Clicking on the Abort button will abort the ramp.
Clicking on the Exit button will exit the Current Ramp screen.
Example 2: Creating a Current ramp using Hardware Trigger mode
Set the Curr to 10A
Set the To Curr to 30A
Set the Volt to 25V
Set the Time to 10s
Connect an appropriate load to the supply
Select the Trigger mode as HW (Hardware)
Click on Initialize
Observe that Trigger Ramp button will change to Waiting for Trig.
Give an external trigger i.e. an active high pulse of 10ms on the MOLEX
connector pin-8 (TRIGGER_IN) and pin-12 (DIN_RTN) to generate the
Current Ramp.
Observe that Waiting for Trig will change to Abort button.
Observe the current ramp signal using oscilloscope
Clicking on the Abort button will abort the ramp.
Clicking on the Exit button will exit the Current Ramp screen.
3.1.7 Configuration Screen
The Configuration power on- settings (PONS), set-up of User V/I Limits, Output Sense,
Measurement Settings and Aux Output.
The top-level menu of the Configuration screen is shown in Figure 3-29. Refer to
Section 3.1.2.1 for navigating to Configuration Screen.