Overview  DC Asterion Series 
3-14  M330460-01  Rev A 
 
Example 1: Creating a Current ramp using Software Trigger mode 
•  Set the Curr to 10A 
•  Set the To Curr to 30A 
•  Set the Volt to 25V 
•  Set the Time to 10s 
•  Connect an appropriate load to the supply 
•  Select the Trigger mode as SW (software) 
•  Click on Initialize 
•  Click on Trigger Ramp 
•  Observe that Trigger Ramp button will change to Abort button 
•  Observe the current ramp signal using oscilloscope 
•  Clicking on the Abort button will abort the ramp. 
•  Clicking on the Exit button will exit the Current Ramp screen. 
 
Example 2: Creating a Current ramp using Hardware Trigger mode 
•  Set the Curr to 10A 
•  Set the To Curr to 30A 
•  Set the Volt to 25V 
•  Set the Time to 10s 
•  Connect an appropriate load to the supply 
•  Select the Trigger mode as HW (Hardware) 
•  Click on Initialize 
•  Observe that Trigger Ramp button will change to Waiting for Trig. 
•  Give an external trigger i.e. an active high pulse of 10ms on the MOLEX 
connector pin-8 (TRIGGER_IN) and pin-12 (DIN_RTN) to generate the 
Current Ramp. 
•  Observe that Waiting for Trig will change to Abort button. 
•  Observe the current ramp signal using oscilloscope 
•  Clicking on the Abort button will abort the ramp. 
•  Clicking on the Exit button will exit the Current Ramp screen. 
3.1.7  Configuration Screen 
The Configuration power on- settings (PONS), set-up of User V/I Limits, Output Sense, 
Measurement Settings and Aux Output. 
The  top-level  menu  of  the  Configuration  screen  is  shown  in  Figure  3-29.  Refer  to 
Section 3.1.2.1 for navigating to Configuration Screen.