Overview  DC Asterion Series 
3-38  M330460-01  Rev A 
5.  Program the Voltage to 10% of rated output by entering the in  the “Setting” 
section on the Dashboard Screen. This programs the Voltage above zero to 
enable supplying output voltage while in the constant-current mode. 
6.  On the Dashboard screen, rotate the rotary knob to select the “Current” text 
box in the “Setting” section. Press the rotary knob to highlight the current value. 
Rotate the rotary knob clockwise and observe both the current display in the 
“Measure” section on the Dashboard screen and output of the DC ammeter 
begin to accelerate up. The output current should increase from 0 A to the 
maximum rated  current of  the  supply.  The  current  display  in  the  “Measure” 
section  on  the  Dashboard  screen  and  DC  ammeter  readings  should  track 
within the accuracies of the meter and the Dashboard. 
7.  Verify the front panel Constant Current Mode LED is on. 
8.  Program the Voltage and Current back to zero. 
9.  Turn the power supply off. 
10. Allow  5 minutes  for  the  output  capacitors to  discharge  and disconnect the 
ammeter or short from the output terminals. 
11. If Constant-Current mode operation did not function as indicated above, verify 
the setup and perform the check again. If the function continues to fail, contact 
the factory for assistance. 
3.2.3  Overvoltage Protection 
The Overvoltage Protection (OVP) function allows the supply to shut down the output, 
if it were to exceed a preset voltage.  This may be used to protect sensitive circuits or 
loads from damage caused by an excessive voltage on the output of the supply. The 
Overvoltage Protection (OVP) could be programmed either through the front panel or 
by the remote analog OVP programming input. To verify OVP operation, follow these 
steps: 
1.  Make sure there is nothing connected across the output terminals. 
2.  Turn on the power supply. 
3.  If the Power ON Settings (PONS) had previously been configured to be OFF, 
when the supply reaches the Dashboard Screen, enable the output by pressing 
the “Output On/Off”. 
4.  Use the Output Program Screen to program the Voltage, Current and OVP. 
5.  Program the Current to 10% of rated output (program the current above zero 
to enable supplying output current while in the constant-voltage mode). 
6.  The factory default setting is approximately 110% of the maximum rated output 
of the supply.  On the Output Program screen, rotate the rotary knob to set the 
“OVP”. Press the rotary knob to highlight the OVP value. Rotate the rotary knob