Figure 3-98.  Remote Current Programming Using Resistance 
 
3.4.2  Remote Current Programming by Voltage Source 
The DC voltage source is connected between Pin 19 (IPRG_VSOUR) and the return Pin 
18 (RTN_PRG) and Analog Reference source is selected as Voltage from  the front 
Panel. Refer to Figure 3-99. 
The Full-Scale voltage value can be modified to any voltage between 2V to 10V from 
front panel screen, refer to Section 3.1.8.3. Default FSC voltage value is 10V, where 
10V  corresponds  to  100%  output  current.  The  corresponding  voltage-programming 
coefficients for output current are (100% rated output current) / FSC VDC. This produces 
transfer functions for output current, as follows:  
Iout = Vdc * (100% rated output current) / 10 VDC), with Vdc in volts, or 
Iout = Vdc * (100% rated output current) / FSC VDC), with Vdc in volts.