WARNING! 
This  unit  is  intended  for  installation  in  a  protected  environment.  Exposure  to 
conductive contaminants or corrosive compounds/gases that could be ingested into 
the  chassis  could  result  in  internal  damage.    Install  the  power  source  in  a 
temperature and humidity controlled indoor area. 
2.4  Rack Mounting 
The Asterion DC Series power source is designed for mounting in a standard 19-inch 
equipment  rack  that  is  compliant  to  ANSI/EIA-310-D.  If  other  instrumentation  is 
mounted in the rack adjacent to the unit, there is no need for additional clearance 
above or below the source. It should be supported in the rack using appropriate L-
brackets or rackmount slides. Refer to Figure 2-1 for typical rackmount installation. 
Recommended rackmount kits are as follows: 
1.  Rackmount Slide Kit (Option): AMETEK part number 5330201-01R. 
2.  Rackmount Flange Bracket Kit (Option): AMETEK part number 5330241-01R. 
Install the rackmount kit as follows: 
1.  Install the slide sections,  1  , on both sides of the power supply chassis with 
screws,   6   , (three on each side). 
2.  Install the brackets,   4   , to the stationary slide sections,   3   , with screws,             
6   , and nuts,   5   , (four on each side). 
3.  Adjust the location of the mounting brackets as required for the particular type 
of rack cabinet vertical rails utilized. 
4.  Mount the stationary slide sections,   3   , (with brackets already installed) into 
the cabinet using appropriate hardware (e.g. the screws and nuts supplied,  8    
and 7  , or user-supplied bar-nuts, cage-nuts, clip-nuts), while ensuring that 
they are level, front to back and left to right, on the cabinet rails.