Preliminary Technical Data UG-1828
Rev. PrC | Page 211 of 338
Figure 195. Configuring Board Configuration Related Parameters Through TES
SAVE AND LOAD DPD COEFFICIENTS FROM LAST TRANSMISSION
The ADRV9001 DPD also provides user an option to save and load DPD coefficients from last transmission. Therefore, DPD could either
start from scratch (unity coefficients) or a set of known coefficients. This is a very useful option if user wants to reach convergence
quickly under a similar transmit operation condition. User could utilize this feature as shown below in the TES.
Figure 196. Save and Load DPD Coefficients from Last Transmission Through TES
DEFINE THE FREQUENCY REGION WHEN PERFORMING DPD WITH FH
As aforementioned, DPD operation can be performed during FH. User can define the 7 frequency regions as shown in TES below: