5-23
5.6 Techniques for Synchronizing the MT8801C with a Controller
<Controller program 2: Synchronization by the sweep/measurement termination bit>
[2] Sets bit 2
0
(1) of the extended END event status enable
register to 1
[3] Sets bit
2
2
(4) of the service request enable register to 1
[4]
Make the device execute the specified operation (measurement)
[5] Waits for SRQ interrupt (ESB summary message)
....Status byte value: 2
6
+ 2
2
= 68
PRINT @1:"*CLS"
[1] Clears the status register
PRINT @1:"ESE2 1"
PRINT @1:"*SRE 4"
to the next operation