2-43
2.5.10 Maintenance commands
Maintenance Mode
Maintenance
TESTMODE TESTLOOPBACK
TESTMODE?
TESTLOOPBACK
*1
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
Mode On
Maintenance TESTMODE? NONE *1
Mode Off
Pilot Channel Pilot channel
Pilot Channel Only
TESTPILOTCH ON
TESTPILOTCH? ON *2
Output On
Pilot channel
TESTPILOTCH OFF
TESTPILOTCH? OFF *2
Output Off
Note 1:
*1 Moves from Idle state to Test Mode (Loop Back) state.
Valid only in CDMA mode with Idle state of Call Proc after Start execution
on Setup Common Parameter screen.
*2 Sets SG output only from Pilot Channel.
Valid only at Test Mode (Loop Back) state.
Note 2:
The usable measurements in the Test Mode of Loop back are the Modulation
Analysis and Power Meter.
Cannot move to the RF Power screen, Open Loop Time Response screen, and
Frame Error Rate screen.
Re-
marks
Query Msg
Intermediate
class
Function Program Msg Response MsgFunction details