NOTE: In the Advanced Wrench Data dialog box the following information are displayed:
• Serial number of the wrench.
• Firmware version.
• Hardware version.
In the Calibration request section, the following check boxes are displayed:
• Date: if selected, it indicates that the calibration is expired, referring to the date.
• Interval: if selected, it indicates that the calibration is expired, referring to the number
of tightening done.
• Overload: if selected, it indicates that an overload occurred.
• Offset: if selected, an error during the zero process occurred.
In the Overload auto reset in cradle section:
• If selected, the Reset enabled check box allows to unlock the wrench after an overload
if the zero procedure in the MWR Charging Cradle is successful.
If the check box is not selected or the zero procedure fails, the wrench remains lock
after an overload.
• If selected, the Set reset flag button allows to enable the reset function for the MWR,
described above.
• The Refresh icon ( ) allows to displayed the saved status of the Reset enable
function.
This section is read-only. To change the Reset enable status, login as Super User is
required.
In the Zero delay setting section:
• The box allows to set the seconds of the zero delay.
• The Refresh icon ( ) allows to displayed the saved status of the Zero delay function.
This section is read-only. To change the Zero delay setting status, login as Super User is
required.
In the Update wrench section:
• If selected, the Upgrade ready check box indicates that the firmware version of the
wrench is older than the firmware version of the wrench saved on Focus 61.
• If selected, the Downgrade check box indicates that the firmware version of the
wrench is most recent than the firmware version of the wrench saved on Focus 61.
• Load firmware allows to upgrade/downgrade the firmware version of the wrench to
the version saved on Focus 61.
Before starting the upgrade/downgrade the MWR firmware, put the MWR on the
MWR Charging Cradle.
This section is read-only. To upgrade/downgrade the firmware version of the wrench, login
as Super User is required.
The Show Ping Status button allows to show ping status information. This section is read
only.
The Adjustment factors button allows to change the default adjustments factors based on the
performed tightening.