Peripheral Devices
508 9836 3521 01
With parameters set as in the above example the input and output areas are mapped as below:
Input to
PowerMACS
Fieldbus side
Output from
PowerMACS
Fieldbus side
0
PLC byte AT 3000
0
0
0
PLC byte AT 3300
0
0
1
PLC byte AT 3001
1
1
1
PLC byte AT 3301
1
1
2
PLC byte AT 3002
2
2
2
PLC byte AT 3302
2
2
:
:
:
:
:
:
:
:
14
PLC byte AT 3014
14
14
14
PLC byte AT 3314
14
14
15
PLC byte AT 3015
15
REAL TIME
IO Data
16 bytes
15
15
PLC byte AT 3315
15
15
0
Data byte In 1
16
0
0
Data byte Out 1
16
16
1
Data byte In 2
17
1
1
Data byte Out 2
17
17
:
:
:
:
:
:
:
62
Data byte In 63
78
62
4
Data byte Out 5
20
20
63
Data byte In 64
79
Acyclic data
block 1
64 bytes
Class id=A2
Inst id=05
Attrib id=05
63
5
Data byte Out 6
21
REAL TIME
IO Data
22 bytes
21
64
Data byte In 65
80
0
6
Data byte Out 7
22
0
65
Data byte In 66
81
1
7
Data byte Out 8
23
1
:
:
:
:
:
:
:
:
126
Data byte In 127
142
62
68
Data byte Out 69
84
62
127
Data byte In 128
143
Acyclic data
block 1
64 bytes
Class id=A2
Inst id=06
Attrib id=05
63
69
Data byte Out 70
85
Acyclic data
block 1
64 bytes
Class id=A2
Inst id=81
Attrib id=05
63
128
Data byte In 129
144
0
70
Data byte Out 71
86
0
129
Data byte In 130
145
1
71
Data byte Out 72
89
1
:
:
:
:
:
:
:
:
190
Data byte In 191
206
62
132
Data byte Out 133
148
62
191
Data byte In 192
207
Acyclic data
block 1
64 bytes
Class id=A2
Inst id=07
Attrib id=05
63
133
Data byte Out 134
149
Acyclic data
block 1
64 bytes
Class id=A2
Inst id=82
Attrib id=05
63
:
:
:
:
:
:
:
:
:
:
383
Data byte In 384
399
0
389
Data byte Out 390
405
0
384
Data byte In 385
400
1
390
Data byte Out 391
406
1
:
:
:
:
:
:
:
:
398
Data byte In 399
414
14
398
Data byte Out 399
414
8
399
Data byte In 400
415
Acyclic data
block 1
64 bytes
Class id=A2
Inst id=0B
Attrib id=05
15
399
Data byte Out 400
415
Acyclic data
block 1
10 bytes
Class id=A2
Inst id=87
Attrib id=05
9
Fast bytes In = 16
Fast bytes Out = 22

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco PowerMACS 4000 and is the answer not in the manual?

Atlas Copco PowerMACS 4000 Specifications

General IconGeneral
BrandAtlas Copco
ModelPowerMACS 4000
CategoryPower Tool
LanguageEnglish

Related product manuals