Version 7.0 387 Mediant 3000
User's Manual 20. Coders and Profiles
Parameter Description
[CodersGroupX_Name]
in the table.
Packetization Time
[CodersGroupX_pTime]
Defines the packetization time (in msec) for the coder. The
packetization time determines how many coder payloads are
combined into a single RTP packet.
Rate
[CodersGroupX_rate]
Defines the bit rate (in kbps) for the coder.
Payload Type
[CodersGroupX_PayloadType]
Defines the payload type if the payload type (i.e., format of the
RTP payload) for the coder is dynamic.
Silence Suppression
[CodersGroupX_Sce]
Enables silence suppression for the coder.
[0] Disable (Default)
[1] Enable
[2] Enable w/o Adaptation =Applicable only to G.729.
Notes:
If silence suppression is not configured for a coder, the
settings of the EnableSilenceCompression parameter is used.
Coder Specific
[CodersGroupX_CoderSpecific]
Defines additional settings specific to the coder.
Currently, the parameter is applicable only to the AMR coder and
is used to configure the payload format type.
[0] 0 = Bandwidth Efficient
[1] 1 = Octet Aligned (default)
Note: The AMR payload type can be configured globally using
the AmrOctetAlignedEnable parameter. However, the Coder
Group configuration overrides the global parameter.