5.4.1 Machine turn off procedure for more than two hours
For machine stoppages longer than 2 hours, follow the procedure below.
STEP ACTION DESCRIPTION
1
Cut-off
compressed
air supply
Turn off the main cut-off valve (turn the knob counter-clockwise) and lock it.
The pneumatic system is disconnected from the pneumatic supply network.
The filters discharge any impurities.
2
Safety warning
DANGER!
The balancing cylinders remain pressurized even after the main switch has
been tagged out.
• Do not tamper with the relative pneumatic pipes to avoid sudden
machine movements.