TWIN Use and maintenance instruction manual
Chap. 6
- 8/32 -
ORDINARY MAINTENANCE TIMETABLE – ELECTRICAL / ELECTRONIC MAINTENANCE
TECHNICIAN
Machine part / component
Personnel
qualification –
Mechanical
support technician
Interval –
Frequency in
hours
Product
Electrical cabinet air conditioner
overhaul
10.000 h
Electrical wiring:
Electrical, electronic and electro-
mechanical components
Machining head electric
manifold check and brush
replacement
Electrical cabinet air conditioner
fan
2000 h
Maintenance frequency is shown in h = hours of operation.
6.3.2 Maintenance interval for multi-shift use of the machine
All indications regarding the maintenance intervals refer to use of the machine for one work shift each
day. If the machine operates for more than one daily shift, the maintenance frequency must be increased
accordingly:
Every 8h of work, that is, at the end of each shift; (every day for a single shift)
Every 40 of work, that is, every 5 shifts;.(every week for a single shift)
Every 160 of work, that is, every 20 shifts; (every month for a single shift)
Every 320 of work, that is, every 40 shifts.(every 2 months for a single shift)
Every 1000 of work, that is, every 125 shifts.(every 6 months for a single shift)
Every 2000 of work, that is, every 250 shifts.(every year for a single shift)
Every 10.000 of work, that is, every 250 shifts.(every 5 years for a single shift)
INFORMATION!