CHAPTER 6 – Maintenance
Chap. 6
- 7/32 -
Machine part / component
Personnel
qualification –
Mechanical
maintenance
technician
Interval –
Frequency in
hours
Product
Pneumatic system:
Visual inspection of tubes,
couplings, etc.
1000 h
Mechanical parts:
Visual inspection of mechanical
components (guides, skids,
bearing screws) and
components subject to wear
(blowers, guards)
1000 h
*1 skids and guides that are not included in the automatic lubrication system.
ORDINARY MAINTENANCE TIMETABLE – ELECTRICAL / ELECTRONIC MAINTENANCE
TECHNICIAN
Machine part / component
Personnel
qualification –
Electrical
maintenance
technician
Interval –
Frequency in
hours
Product
Electrical system:
Visual inspection: cables and
connections
Check safety devices
1000 h
ORDINARY MAINTENANCE TIMETABLE – MECHANICAL SUPPORT TECHNICIAN
Machine part / component
Personnel
qualification –
Mechanical
support technician
Interval –
Frequency in
hours
Product
Pneumatic system:
Solenoid valve check (heating
and binding) and replacement
as required
FRL unit check and replacement
as required
2000 h
2000 h
Mechanics:
Check correct tautness of
transmission belts
Check that mechanical parts are
tight (ring nuts, flanges, etc.)
2000 h
2000 h