5.5 Machine stop and re-start
The paragraphs below describe the procedures to be followed to stop the machine and interrupt or cut-
off power supplies.
In fact, there are three different types of machine stops that the user may execute to stop the machine
running.
• The “Emergency” stop is carried out in the event it becomes necessary to immediately block the
machine due to a risk or unforeseen event; the program being run stops immediately and all
movements are slowed down at the maximum deceleration possible. Electric power is cut-off and the
auxiliaries turn off.
• The working "Stop" is used to stop the program being run without fully stopping all machine
functions. This kind of stop is executed by pressing the “STOP” button on the main panel; the
program being run stops immediately and all movements are slowed down at the deceleration set in
the software parameters. Electric power is not cut-off. The auxiliaries remain turned on.
• The “Reset” stop is used to stop a machining cycle and stop the program by pressing the “Reset”
pushbutton on the main panel or the “Reset” key in the lower right hand corner of the monitor. We
recommend executing this stop only during cycle standby moment.