2.16.12 Residual risks during adjustments with laser devices
2.16.12.1 Adjustments with laser devices – (Risk ID: 17.01)
IDENTIFICATION RISK ASSESSMENT
Stage: Maintenance
Person: Maintenance personnel
Area: Z00 All areas
Initial risk: MEDIUM
RESIDUAL RISK: LOW
PLr (EN 13849): -
SIL (EN IEC 62061): -
ACCIDENT SCENARIO
Consequence:
6.2 Injury to eyes and skin.
Situation:
Standing near the laser adjustment device.
Event:
Risk of injury to eyes looking directly into the laser beam.
Body part:
Eyes.
RESIDUAL RISK
Risk of injury to eyes looking directly into the laser beam.
LIMITATION MEASURES
Mechanical:
The photocells are positioned in such a way as to avoid the laser beam from
pointing directly into the operator’s eyes.
Electrical:
-
Informative:
Take care never to look directly into the laser beam.
A warning sticker bearing the warning below is located near the lawer:
CLASS 2 LASER
DO NOT STAND NEAR THE LASER BEAM.
Symbols:
Placement of a sticker warning of the presence of a class 2 laser (WARNING
AP05)