7. ICMP
7.7 ICMP conguration via Communicato r
About ICMP conguration
Following parameters a re available to congure the ICMP:
Global settings: allows dening nam e of the ICMP, host nam e (network identier) and IP address which can be used for com -
munication with external content dev ices.
User settings: denition of all users allowed on the ICM P.
Server settings: denition of access to servers and storage libraries of content (movies, KDM, etc.).
Player settings: Audio delay and audio output frequency.
Audio channel: allows den ing the mapping of audio channels (content) on each audio output (AES outputs of the ICMP).
Scheduler setting: Enable/Disable scheduler at startup, delays allowed in scheduler mode and length of schedule history.
Devices: allows dening communication ports settings, to access external devices controlled by the au tomation.
Automation Cues: ev ent cues that are triggered from different sources and to which can be assigned actions to be executed
by the autom ation eng ine.
Verify internal clock of the ICMP.
All installation and maintenance operations on the ICMP are performed via Communicator, the Barco cong-
uration software. P lease refer to the Communicator user guide for f urther information.
About Default settings
The restore of factory setting is a feature that allows rem oving all settings performed o n the ICM P and replaces them with the default
values set at the factory. P lease refer to the Communicator user guide for further information.
About the ICMP internal clock
The crystal on the ICMP board that manages the clock shows a certain drift ( all crystals do). W ith the Com m unicator the internal
clock can be adjusted. This maintenance action should be repea ted every 3 m onths. When neglected the system will locks up.
From ICMP software version 1.2.1 onwards it is possible to enable NTP (N etwork Time Protocol). You have to congure (at instal-
lation) an IP address where the ICM P can nd a s ync signal. From then on, and as long as the connection is ac tive, the ICMP will
automatically keep its clock correct. Fo r de tailed instructions see u ser guide of the Communicator.
116
R5905963 PROMETHEUS SERIES 09/03/2015

Table of Contents

Other manuals for Barco Prometheus I

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Barco Prometheus I and is the answer not in the manual?

Barco Prometheus I Specifications

General IconGeneral
BrandBarco
ModelPrometheus I
CategoryProjector
LanguageEnglish

Related product manuals