4. Lamp & Lamp House
4.9 Check if anode support must be provided with a plain washer
Necessary tools
• 2.5mm Allen wrench.
• 19mm ope n-end wrench.
Necessary parts
Plain washe r, stainless steel, ØD = 18m m, Ød = 6.4mm, thickness = 1 .6mm. (V3673807).
How to check if the anode support must be provided with a plain washer?
1. Turn the thumbscrew of the Z direction counterclockwise as for as possible (minimum Z position of the xenon lamp).
2. Check if the anode pin of the xenon lamp remains supported by the anode support.
Image 4-47
3. In case the anode pin d rops out the anode support place a plain washer (reference 3) between the UV blocker and anode support
(reference 4). Use a 2.5mm Allen w rench to loosen/fasten the screw (reference 1) of the anode support. Use a 1 9mm open-end
wrench to capture the anode support.
1
2
4
3
Image 4-48