3
Move several times the clutch lever to fill the circuit and bleeding the air.
Connect the bleeding device to the bleeding valve (2).
NOTES
When using a bleeding device, follow the manufacturer’s instructions.
Pump with the bleeding device and loosen the drain valve (2) checking always that the level does
not fall below the MIN.
Repeat this step until any more air bubbles does not appear in the transparent hose connected to
the bleeding valve.
In case a bleeding device is not available connect a transparent plastic hose to the drain valve (2)
as described for the circuit bleeding.
Open the bleeding valve of ¼ of turn and operate the clutch lever until the fluid start to come out
from the valve (2) then close the draining valve. Pull completely the clutch lever then loosen the
bleeding valve at least of ¼ of turn.
Wait a few seconds; close the draining valve (2) then slowly release the lever.
IMPORTANT
Do not release the clutch lever if the valve is not well tighten.