Operating instructions CS 300 Technical data
6.110.98.5.01.40 en 10 - 3
10
10.3 Power supply
The electrical power supply must comply with the national requirements and tolerances.
Technical data of power supply
Mains supply
Single-phase AC voltage, see data on identification plate.
220 V / 230 V
110 V / 120 V
Permissible mains
voltage tolerance
(steady-state) normal:
+6% to - 10% of nominal value
Mains frequency: 50 (60) Hz
Permissible tolerance
of mains frequency:
+2 to -2%
Admissible distortion
factor of mains volt-
age:
<=5%
Leakage current pro-
tective conductor
max.:
3.5 mA
Plug-in transformer unit
Bizerba devices are built according to VDE protection
(extra-low voltage) and must be
connected to a plug-in power supply unit with extra-low voltage. Nominal value: 9V DC 500
mA.
For direct plug-in transformer units:
This product is to be power-supplied via a listed plug-in transformer unit
with identification class 2 and the electric nominal values 9V DC,
500mA.
10.4 Ambient conditions
Strictly adhere to the following requirements when applying electronic retail scales weigh-
ing and EDP systems, recording units and similar devices, device combinations and spare
parts.
For other manufacturers' equipment included in Bizerba's scope of supply, the respective
manufacturer's regulations take preference if they deviate from Bizerba's conditions.