Control Panels Appendix | en 133
Bosch Security Systems, Inc. Installation Manual 2018.07 | 16 | F.01U.287.180
Panel event Modem4 code
D6500 mode
Modem4 code
Bosch SIA mode
Contact ID event Contact ID code
AC Restore - mains power
supply
Rsss0 NAR AC failure restore 3 301 00 000
Add Key Fob to a User
(Assign Card Event)
NsD30 NidiiiiDAiiii Local Only Local only
Alarm Aspppp NriaBApppp Burglary 1 130 aa ppp
Alarm Cross Point Aspppp NriaBMpppp Burglary 1 130 aa ppp
Alarm Exit Error Aspppp Nria/idiiiiEApppp Entry/Exit 1 134 aa ppp
Alarm with Recent Closing Aspppp Nria/CRpppp Entry/Exit 1 459 aa uuu
All Points Tested by User RsssF NRilTC Local Only Local Only
All SDI devices are missing,
power is shorted
TsssD NpiET Expansion Module Failure 1 333 00 000
All SDI devices are restored,
power is normal
RsssD NpiER Expansion Module Failure
Restore
3 333 00 000
An invalid RPS or Installer
Services Portal programming
tool (available in Europe,
Middle East, Africa, and
China) remote access
callback occurred
TsssF Np004RU Unsuccessful Access 1 413 00 000
An invalid RPS or Installer
Services Portal programming
tool (available in Europe,
Middle East, Africa, and
China) remote access
occurred
TsssF NRU Unsuccessful Access 1 413 00 000
Area Watch End NsD52 Nriaa/idiiiiTZ Local Only Local Only
Area Watch Start NsD51 Nriaa/idiiiiTW Local Only Local Only
Armed PartOn delay Csiiii Nriaa/idiiiiNL Armed STAY 3 441 aa uuu
Armed PartOn instant Csiii Nriaa/idiiiiNL Armed STAY 3 441 aa uuu
Aux Overload Tsss9 NYM Low System Battery 1 302 00 000
Aux Overload Restore Rsss9 NYR Low System Battery
Restore
3 302 00 000
Battery Charger Circuit
Trouble
Tsss9 NYT System Trouble 1 300 00 000
Battery Charger Circuit
Trouble Restoral
Rsss9 NYR System Trouble Restore 3 300 00 000
Bypass by Sked Nspppp Nriaa/
aikkkUBpppp
Zone/Sensor Bypass 1 570 aa ppp