134 en | Appendix Control Panels
2018.07 | 16 | F.01U.287.180 Installation Manual Bosch Security Systems, Inc.
Panel event Modem4 code
D6500 mode
Modem4 code
Bosch SIA mode
Contact ID event Contact ID code
Bypass by User Nspppp Nriaa/
idiiiiUBpppp
Zone/Sensor Bypass 1 570 aa ppp
Cellular Fewer than Two
Towers
TssssD NpiddddET System Peripheral Trouble 1 330 00 zzz
Cellular Fewer than Two
Towers Restoral
RssssD NpiddddER System Peripheral Trouble
Restore
3 330 00 zzz
Cellular Low Signal TssssD NpiddddET System Peripheral Trouble 1 330 00 zzz
Cellular Low Signal Restoral RssssD NpiddddER System Peripheral Trouble
Restore
3 330 00 zzz
Cellular No Tower Available TssssD NpiddddET System Peripheral Trouble 1 330 00 zzz
Cellular No Tower Available
Restoral
RssssD NpiddddER System Peripheral Trouble
Restore
3 330 00 zzz
Cellular Service Not Activated TssssD NpiddddET System Peripheral Trouble 1 330 00 zzz
Cellular Service Not Activated
Restoral
RssssD NpiddddER System Peripheral Trouble
Restore
3 330 00 zzz
Change another’s password
or card
NsDO4 NidiiiiiJViiiii Local Only Local Only
Change own password NsDO4 NidiiiiiJViiiii Local Only Local Only
Checksum failure on
configuration memory
TsD15 NYF RAM Checksum Bad 1 303 00 000
Closing by Account Csiiii NidiiiiCL O/C by account 3 401 00 uuu
Closing by Area Csiiii Nriaa/idiiiiCL O/C by User 3 401 aa uuu
Closing Early by Area Csiiii Nriaa/idiiiiCK Early O/C 3 451 aa uuu
Closing Late by Area Csiiii Nriaa/idiiiiCJ Late O/C 3 452 aa uuu
Communication failure by
route group
TsB01 NrggYC Failure to communicate
event
1 354 00 000
Communication failure by
route group restored
NsB01 NrggYK Failure to communicate
event
3 354 00 000
Communication trouble by
network
TsB01 NpiddddYS Communication Trouble 1 350 00
1
zzz
Communication trouble by
network restored
NsB01 NpiddddYK Communication Trouble
Restore
3 350 00
1
zzz
Communication trouble by
phone
TsB01 NphhhYS Communication Trouble 1 350 00 000
Communication trouble by
phone restored
NsB01 NphhhYK Communication Trouble
Restore
3 350 00 000

Table of Contents

Other manuals for Bosch B4512

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch B4512 and is the answer not in the manual?

Bosch B4512 Specifications

General IconGeneral
Control Panel TypeHybrid
Wired Zones8
Outputs2
Programmable Outputs2
Onboard EthernetYes
Cellular CommunicationOptional
SeriesB Series
Partitions2
TypeControl Panel
ModelB4512
ManufacturerBosch
Input Voltage16.5 VAC
Communication FormatsContact ID, SIA
Power Supply16.5 VAC
Backup Battery12 V, 7 Ah
Operating Temperature0°C to +50°C
Weight1.5 kg
CompatibilityBosch accessories