After you enter a phone number in the Phone Number 1 field, the router allows you to
configure the control of the device using an SMS message. You can configure up to three
numbers for incoming SMS messages. To enable the function, mark the Enable remote control
via SMS check box. The default setting of the remote control function is active. Note: Every
received control SMS is processed and then deleted from the router.
Item Description
Phone Number 1 Specifies the first phone number allowed to access the router us-
ing an SMS.
Phone Number 2 Specifies the second phone number allowed to access the router
using an SMS.
Phone Number 3 Specifies the third phone number allowed to access the router
using an SMS.
Table 59: Control via SMS
If you leave the phone number field blank, then you can restart the router using an
SMS Reboot message from any phone number.
If you enter one or more phone numbers, then you can control the router using SMS
messages sent only from the specified phone numbers.
If you enter the wild card character , then you can control the router using SMS
messages sent from any phone number.
Control SMS messages do not change the router configuration. For example, if the router is
changed to the off line mode using an SMS message, then the router remains in this mode.To
return the router to the on-line mode, reboot or power cycle the device. The behavior is the
same for every SMS control message.
To control the router using an SMS, send only message text containing the control com-
mand. You can send control SMS messages in the following form:
SMS Description
go online sim 1 The router changes to SIM1
go online sim 2 The router changes to SIM2
go online Changes the router to the online mode
go offline Changes the router to the off line mode
set out0=0 Sets the binary output to 0
set out0=1 Sets the binary output to 1
Continued on next page