7. General Configuration Setting
7-2-5-5 Transmission Timeout
After sending the information, how long time did not respond will start timeout
*8BF+*
7-2-5-6 Transmission Char Delay
After setting the number of characters transmitted into the Delay Time
*0BG+*
Configuration Range Unit Default Setting
2 ~ 255 secs 1 sec 3 secs
Procedure: Example:
(A) Scan “Enter” barcode
(B) Scan “Transmission Timeout”
barcode
(C) Scan parameters from
Hexadecimal / Decimal table
(D) Scan “OK“ barcode
(E) Scan “End” barcode
If configuration is 2 sec, the
parameter value is 2 sec / 1 sec = 2
Configuration Range Default Setting
0 ~ 255 0
Procedure
(A) Scan “Enter” barcode
(B) Scan “Transmission Char Delay” barcode
(C) Scan parameters from Hexadecimal / Decimal table
(D) Scan “OK“ barcode
(E) Scan “End” barcode