8. Symbology Settings
8-18-13 Insertion1Data
To set up data1 to be inserted
*L0S+*
Code39
*FSM+*
Code32
Procedure:
(A) Scan “Enter” barcode
(B) Scan “Insertion1Data” barcode
(C) Scan parameters from Hexadecimal / Decimal table
(D) Scan “OK“ barcode
(E) Scan “End” barcode
8-18-14 Insertion2DataPosition
To set up the position to insert data2
*N0U+*
Code39
*HSO+*
Code32
Procedure:
(A) Scan “Enter” barcode
(B) Scan “Insertion2DataPosition” barcode
(C) Scan parameters from Hexadecimal / Decimal table
(D) Scan “OK“ barcode
(E) Scan “End” barcode
Type Configuration Length
Default Setting
Code39 2 NULL
Code32 2 NULL
Type Configuration Range
Default Setting
Code39 0~48 0
Code32 0~48 0
8-18-13 Insertion1Data