4-4
Each program has a Run Count that sets the execution number.
Table 4-1 lists the Run Count range:
Table 4-1
RUN COUNT
MIN
MAX
TIMES
1
15000
Ex. 1: Set RUN COUNT for a program
Set Prog Chain =3, Run Count=2 for Prog No.1.
Set Prog Chain =No, Run Count=2 for Prog No.3.
The program execution flow of Run Count is listed in Figure 4-5.
A1: Execution steps:
(1) When all Prog No.1 sequences are done, return to Prog No.1.
(2) Repeat step (1) twice and skip Prog No.2 and jump to Prog No.3.
(3) When all Prog No.3 sequences are done, return to Prog No.3.
(4) Repeat step (3) twice.
(5) End
Figure 4-5
4.1.1.4 Setting Program Chain
Tap Prog Chain on the right and select NO” or set the value from 1~10.
The Program Chain indicates the link among programs. To execute a different program,
select the next Prog No. to be executed. The setting range is 0 ~ 10.
When the value is set to 1~10, it means to chain the programs as the example shown below.
Ex. 2: Chain among programs
Set Prog Chain =3, Run Count=1 for Prog No.1.
Set Prog Chain =6, Run Count=1 for Prog No.3.
Set Prog Chain =No, Run Count=1 for Prog No.6.