Programmable Bidirectional DC Power Supply 62000D Series
Operating and Programming Manual
5-8
SYSTem:ERRor?
Returns the error message and code of
power supply.
SYSTem:MODE
Sets the Source/Load output mode of the
system.
SYSTem:VERSion:INTernal?
Queries the Host version
SYSTem:MODule:VERSion?
Queries the module version.
SYSTem:DATE
Sets the system date.
SYSTem:TIME
Sets the system time.
SYSTem:COMMunicate:CAN:CYClic:TIME
Sets the CAN cycle time.
SYSTem:COMMunicate:CAN:CYClic:ID
Sets the CAN cycle command ID.
SYSTem:COMMunicate:CAN:BAUD
Sets the CAN baudrate.
SYSTem:COMMunicate:CAN:ID
Sets the CAN ID.
SYSTem:COMMunicate:CAN:MASK
Sets the CAN ID mask.
SYSTem:COMMunicate:CAN:MODE
Sets the CAN 11 bit / 29 bit mode.
SYSTem:COMMunicate:CAN:PADding
Sets the CAN padding function.
SYSTem:COMMunicate:CAN:SCPI:ID
Sets the CAN SCPI ID.
SYSTem:COMMunicate:CAN:APPLY
Updates the CAN setting.
SYSTem:COMMunicate:GPIB:ADDRess
Sets the GPIB address.
SYSTem:COMMunicate:SOCK:DHCP
Sets the Ethernet DHCP function.
SYSTem:COMMunicate:SOCK:GATEway
Sets the Ethernet Gateway.
SYSTem:COMMunicate:SOCK:IP
Sets the Ethernet IP.
SYSTem:COMMunicate:SOCK:MASK
Sets the Ethernet IP Mask.
SYSTem:COMMunicate:SOCK:APPLY
Updates the Ethernet setting.
INSTrument:STATus:AD?
Returns the AD module status.
INSTrument:STATus:DD?
Returns the DD module status.
5.6.1 Common Command Syntax
Commands are defined by IEEE488.2 standard containing common and query commands.
Common commands begin with a “*” and consist of three letters and/or one “?” (query).
Common commands and queries are listed alphabetically.
*CLS Clear Status
Type: Device status
Description: *CLS command acts the follows:
Clear Error Code Reset Error Message. If “*CLS” is followed by <nl>, the
“output queue” and MAV bit will be clear as well.
Syntax: *CLS
Parameter: None
*ESE Standard Event Status Enable
Type: Device status
Description: This command sets the condition of the Standard Event Status Enable
register, which determines which events of the Standard Event Status
Event register (see *ESR?) are allowed to set the ESB (Event Summary
Bit) of the Status Byte register. A "1" in the bit position enables the
corresponding event. All of enable events of the Standard Event Status
Event register are logically ORed to cause the ESB (bit 5) of the Status
Byte register to be set.
Syntax: *ESE <NRf>

Table of Contents