Programmable Bidirectional DC Power Supply 62000D Series
Operating and Programming Manual
1-4
Programming
&Measurement
Resolution
Voltage (Front Panel )
10mV
Current (Front Panel)
10mA
Voltage (Digital
Interface)
0.002% of Vmax
Current (Digital
Interface)
0.004% of Imax
Voltage (Analog
Interface )
0.04% of Vmax
Current (Analog
Interface )
0.04% of Imax
Remote Interface
Analog programming
Standard
USB
Standard
GPIB
Optional
CAN
Optional
LXI Compliant LAN
Interface
Standard
Programming
Accuracy
Voltage (Front Panel
and Digital Interface )
0.05% of Vmax
Current (Front Panel and
Digital Interface )
0.2% of Imax
Power (Front Panel and
Digital Interface)
0.3% of Pmax
Voltage (Analog
Interface)
0.2% of Vmax
Current (Analog
Interface)
0.3% of Imax
APG Measure
Accuracy
Voltage (Analog
Interface)
0.5% of Vmax
Current (Analog
Interface)
0.75% of Imax
GPIB Command
Response Time
Vout setting
GPIB send command to DC source receiver <20ms
Measure Volt & Current
Under GPIB command using Measure <25ms
Analog Interface (I/O)
Voltage and Current
Programming inputs
(I/P)
Voltage: 0 - 10Vdc of F.S.
Current: Source I = 0 - 10Vdc of F.S.
Load I = 0 - 10Vdc of F.S.
Voltage and Current
monitor output (O/P)
Voltage: 0 - 10Vdc of F.S.
Current : -10 - 10Vdc of F.S.
External ON/OFF (I/P)
TTL: Active Low or High (Selective)
DC_ON Signal (O/P)
Level by user defined. (Time delay= 1ms at voltage slew rate of
10V/ms.)
CV or CC mode
Indicator (O/P)
TTL Level High=CV mode;
TTL Level Low=CC mode
OTP Indicator (O/P)
TTL: Active Low

Table of Contents