Default SettingFeature
Keepalive: 60 seconds; holdtime: 180 seconds.Timers
1
Nonstop Forwarding
2
NSF Awareness can be enabled for IPv4 on switches with the Network Advantage license by enabling Graceful Restart.
Enabling BGP Routing
Before You Begin
To enable BGP, the switch or stack master must be running the Network Advantage license.Note
Procedure
PurposeCommand or Action
Enters the global configuration mode.configure terminal
Example:
Device# configure terminal
Step 1
Enables IP routing.ip routing
Example:
Device(config)# ip routing
Step 2
Enables a BGP routing process, assign it an AS
number, and enter router configuration mode. The AS
router bgp autonomous-system
Example:
Device(config)# router bgp 45000
Step 3
number can be from 1 to 65535, with 64512 to 65535
designated as private autonomous numbers.
Configures a network as local to this AS, and enter it
in the BGP table.
network network-number [mask
network-mask] [route-map
route-map-name]
Step 4
Example:
Device(config)# network 10.108.0.0
Routing Configuration Guide, Cisco IOS XE Everest 16.6.x (Catalyst 9500 Switches)
126
Configuring IP Unicast Routing
Enabling BGP Routing

Table of Contents

Other manuals for Cisco Catalyst 9500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 9500 Series and is the answer not in the manual?

Cisco Catalyst 9500 Series Specifications

General IconGeneral
SeriesCatalyst 9500 Series
CategorySwitch
SoftwareCisco IOS XE
Operating Temperature0°C to 45°C (32°F to 113°F)
Storage Temperature-40°C to 70°C (-40°F to 158°F)
Fixed Uplink ModulesVaries by model
StackingYes (StackWise Virtual)
RedundancyRedundant power supplies and fans
SecurityAdvanced security features
PoE+Available (varies by model)
Power Supply OptionsAC and DC options (varies by model)
Relative Humidity5% to 90% noncondensing
Dimensions (H x W x D)Varies by model
WeightVaries by model
PortsUp to 48 ports (varies by model)

Related product manuals