Citrix SD-WAN Platforms
tions.
Deploying a Citrix SD-WAN VPX instance on an SDX appliance includes the following tasks:
Installing the hardware: ensure the SDX hardware is properly installed. For more information,
see Installing the Hardware.
Setting up and configuring the SDX Management Service. For more information, see Getting
Started with the Management Service User Interface and Configuring the Management Service.
Provisioning the SD-WAN VPX instance on the SDX appliance. For more information, see Provi-
sion the Citrix SD-WAN VPX instance on a Citrix ADC SDX.
Configuring the SD-WAN VPX instance. For more information, see the Configuration documen-
tations and Configuring the virtual path service between the MCN and client sites.
Prerequisites
Ensure you’ve the following licenses:
Citrix SD-WAN VPX license
Citrix ADC SDX platform license
Citrix SD-WAN VPX requirements
The Citrix SD-WAN VPX on SDX platform can act both as a site and MCN. The MCN can handle 1 Gb/s
bidirectional throughput and 64 sites.
Supported throughput for MCN and site
250 Mb/s to 1 Gb/s bidirectional throughput
MCN supports 64 sites
Hardware requirement for supported throughput
Site
4 CPUs to 16 CPUs
4 GB to 16 GB RAM
60 GB to 250 GB disk storage
Minimum 4 NICs: one for management and remaining minimum 3 for data path
Master control node (MCN)
4,8, and 16 CPUs
16 GB RAM
250 GB disk storage