4-50 Compaq AlphaServer ES40 Service Guide
PWR1 00 30-49448-01. C02 2P91600530 API-7650
FAN1 00 70-40073-01 - Fan
FAN2 00 70-40073-01 - Fan
FAN3 00 70-40072-01 - Fan
FAN4 00 70-40071-01 - Fan
FAN5 00 70-40073-02 - Fan
FAN6 00 70-40074-01 - Fan
SMB0.CPB0.SBM0 06 54-12345-01 AY80151237
➊
FRUname The FRU name recognized by the SRM console. The name
also indicates the location of that FRU in the physical
hierarchy.
SMB = system motherboard; CPU = CPUs; MMB = memory
motherboard; DIM = DIMMs; CPB = PCI backplane; PCI =
PCI option; SBM = SCSI backplane; PWR = power supply;
FAN = fans; JIO= I/O connector module (junk I/O).
➋ E Error field. Indicates whether the FRU has any errors
logged against it. FRUs without errors show 00 (hex).
FRUs with errors have a non-zero value that represents a
bit mask of possible errors. See Table 4–3.
➌
Part # The part number of the FRU in ASCII, either a Compaq
part number or a vendor part number.
➍ Serial # The serial number. For Compaq FRUs, the serial number
has the form XXYWWNNNNN.
XX = manufacturing location code
YWW = year and week
NNNNN = sequence number. For vendor FRUs, the 4-byte
sequence number is displayed in hex.
➎ Model/Other Optional data. For Compaq FRUs, the Compaq part alias
number (if one exists). For vendor FRUs, the year and
week of manufacture.
➏ Alias/Misc Miscellaneous information about the FRUs. For Compaq
FRUs, a model name, number, or the common name for the
entry in the Part # field. For vendor FRUs, the
manufacturer's name.