Using the Remote Management Console 7-15
7.6.1 Defining the COM1 Data Flow
Use the set com1_mode command from SRM or RMC to define the
COM1 data flow paths.
You can set com1_mode to one of the following values:
through
snoop
soft_bypass
firm_bypass
local
All data passes through RMC and is filtered for the escape
sequence. This is the default.
Data partially bypasses RMC, but RMC taps into the data lines
and listens passively for the escape sequence.
Data bypasses RMC, but RMC switches automatically into
Snoop mode if loss of carrier occurs.
Data bypasses RMC. RMC remote management features are
disabled.
Changes the focus of the COM1 traffic to the local MMJ port if
RMC is currently in one of the bypass modes or is in Through
mode with an active remote session.
Example 7–1 set com1_mode
RMC> set com1_mode
Com1_mode (THROUGH, SNOOP, SOFT_BYPASS, FIRM_BYPASS, LOCAL): local
NOTE: For more details, see the Compaq AlphaServer ES40 User Interface
Guide.