7-18 Compaq AlphaServer ES40 Service Guide
7.6.3 Displaying the System Environment
The RMC env command provides a snapshot of the system
environment.
Example 7–3 env
RMC> env
System Hardware Monitor
Temperature (warnings at 45.0°C, power-off at 50.0°C)
CPU0: 26.0°C CPU1: 26.0°C CPU2: 27.0°C CPU3: 26.0°C
Zone0: 29.0°C Zone1: 30.0°C Zone2: 31.0°C
Fan RPM
Fan1: 2295 Fan2: 2295 Fan3: 2205
Fan4: 2235 Fan5: OFF Fan6: 2518
Power Supply(OK, FAIL, OFF, '----' means not present)
PS0 : OK PS1 : OK PS2 : ----
CPU0: OK CPU1: OK CPU2: OK CPU3: OK
CPU CORE voltage
CPU0: +2.192V CPU1: +2.192V CPU2: +2.192V CPU3: +2.192V
CPU IO voltage
CPU0: +1.488V CPU1: +1.488V CPU2: +1.488V CPU3: +1.488V
Bulk voltage
+3.3V Bulk: +3.328V +5V Bulk: +5.076V +12V Bulk: +12.096V
Vterm: +1.824V Cterm: +2.000V -12V Bulk: -12.480V