Troubleshooting 2-5
Table 2–2 Problems Getting to Console Mode
Symptom Action Reference
Power-up screen is not
displayed at system
console.
Note any error beep codes and
observe the OCP display for a
failure detected during self-tests.
Check keyboard and monitor
connections.
Press the Return key. If the system
enters console mode, check that the
console environment variable is set
correctly.
Chapter 3
Chapter 1
If the console terminal is a VGA
monitor, the console variable
should be set to graphics. If it is a
serial terminal, the console
environment variable should be set
to serial.
If console is set to serial, the
power-up screen is routed to the
COM1 serial communication port or
MMJ port and cannot be viewed
from the VGA monitor.
Chapter 6
Try connecting a console terminal to
the COM1 serial communication
port. When using the COM1 port
set the console environment
variable to serial.
Chapter 6
Use RMC commands to determine
status.
Chapter 7