Error Logs 5-15
Table 5–2 Machine Checks/Interrupts (Continued)
Error Type Error Descriptions
System Correctable Error
(620)
ES40-specific correctable
errors.
System detected ECC single-bit error
System Uncorrectable Error
(660)
A system-detected machine
check that occurred as a
result of an “off-chip” request
to the system.
Uncorrectable ECC error
Nonexistent memory reference
PCI system bus error (SERR)
PCI read data parity error (RDPE)
PCI address/command parity error (APE)
PCI no device select (NDS)
PCI target abort (TA)
Invalid scatter/gather page table entry (SGE)
error
PCI data parity error (PERR)
Flash ROM write error
PCI target delayed completion retry time-out
(DCRTO)
PCI master retry time-out (RTO 2**24) error
PCI-ISA software NMI error
System Environmental Error
(680)
System-detected machine
check caused by an
overtemperature condition,
fan failure, or power supply
failure.
Overtemperature failure (>50•C) (see Note)
Uncorrectable Fan 5 failure
Complete power supply failure
Fan failure (redundant fan)
Power supply failure (redundant supply)
High temperature warning (>45 C and
<50• C)
NOTE: For overtemperature failure, the position of jumper J26 determines
whether the failure is fatal or nonfatal. See Appendix B.

Table of Contents

Other manuals for Compaq AlphaServer ES40

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Compaq AlphaServer ES40 and is the answer not in the manual?

Compaq AlphaServer ES40 Specifications

General IconGeneral
BrandCompaq
ModelAlphaServer ES40
CategoryServer
LanguageEnglish

Related product manuals