6-14 Compaq AlphaServer ES40 Service Guide
Table 6–1 SRM Environment Variables Used on ES40 Systems
(Continued)
Variable Attributes Description
boot_osflags
(continued)
D—Full dump; implies s as well. By default, if
Tru64 UNIX crashes, it completes a partial
memory dump. Specifying D forces a full dump at
system crash.
Common settings are a, autoboot, and Da,
autoboot and create full dumps if the system
crashes.
com1_baud
NV,W
Sets the baud rate of the COM1 (MMJ) port. The
default baud rate is 9600.
Baud rate values are 1800, 2000, 2400, 3600,
4800, 7200, 9600, 19200, 38400, 57600.
com2_baud
NV,W
Sets the baud rate of the COM2 port. The default
baud rate is 9600.
Baud rate values are 1800, 2000, 2400, 3600,
4800, 7200, 9600, 19200, 38400, 57600.
com1_flow
com2_flow
NV,W
The com1_flow and com2_flow environment
variables indicate the flow control on the serial
ports. Defined values are:
none—No data flows in or out of the serial ports.
Use this setting for devices that do not recognize
XON/XOFF or that would be confused by these
signals.
softwareUse XON/XOFF(default). This is the
setting for a standard serial terminal.
hardwareUse modem signals CTS/RTS. Use
this setting if you are connecting a modem to a
serial port.
com1_mode
NV
Specifies the COM1 data flow paths so that data
either flows through the RMC or bypasses it.

Table of Contents

Other manuals for Compaq AlphaServer ES40

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Compaq AlphaServer ES40 and is the answer not in the manual?

Compaq AlphaServer ES40 Specifications

General IconGeneral
BrandCompaq
ModelAlphaServer ES40
CategoryServer
LanguageEnglish

Related product manuals