Using the Remote Management Console 7-31
The following procedure restores the default settings:
1.
Shut down the operating system and press the Power button on the operator
control panel to the OFF position.
2.
Unplug the power cord from each power supply. Wait until the +5V Aux
LEDs on the power supplies go off before proceeding.
3.
Remove enclosure panels as described in Chapter 8.
4.
Remove the system card cage cover and fan cover from the system chassis,
as described in Chapter 8.
5.
Remove CPU 1 as described in Chapter 8.
6.
On the system motherboard, install jumper J25 over pins 1 and 2. See
Figure 7–4. (The default jumper positions are shown.)
7.
Plug a power cord into one power supply and wait for the control panel to
display the message “System is down.”
8.
Unplug the power cord. Wait until the +5V Aux LED on the power supply
goes off before proceeding.
9.
Install jumper J25 over pins 2 and 3.
10.
Reinstall CPU 1, the card cage cover and fan cover, and the enclosure
panels.
11.
Plug the power cord into each of the power supplies.
NOTE: After the RMC has been reset to defaults, perform the setup procedures
to enable remote dial-in and call-out alerts. See Section 7.6.6.