Loading...
FRU Removal and Replacement 8-39
Removing the Floppy Drive
You must shut the system down before removing the floppy drive.
1.
Remove the cover to the PCI card cage.
2.
Remove and set aside the four screws
that secure the removable media
cage.
3.
Unplug the signal cable
and power cable from all devices except the
floppy.
4.
Remove the cage.
5.
Unplug the signal cable and power cable from the floppy.
6.
Remove the four screws
that secure the floppy drive, and slide the drive
out.
7.
Remove the mounting brackets
(two screws in each bracket) from the
drive.