Application Guide | iC2-Micro Frequency Converters
Data type: uint16 Access type: Read/Write
P 5.6.15 Sync. High Starting Torque Time [s]
Use this parameter to set the high starting torque time for a PM motor in VVC+ mode.
Default value: Size Related Parameter type: Range (0.00–60.00)
Parameter
number:
3020 Unit: s
Data type: uint16 Access type: Read/Write
P 5.6.16 Sync. High Starting Torque Current [%]
Use this parameter to set the high starting torque current for a PM Motor in VVC+ mode.
Default value: Size Related Parameter type: Range (0.0–200.0)
Parameter
number:
3021 Unit: %
Data type: uint 32 Access type: Read/Write
7.6.6 Stop Settings (Menu Index 5.7)
P 5.7.1 Function at Stop
Use this parameter to select the drive function after a stop command or after the speed is ramped down to the level set in P 5.7.2 Min
Speed for Function at Stop [Hz].
Default value: 0 [Coast] Parameter type: Selection
Parameter
number:
180 Unit:
Data type: enum Access type: Read/Write
The following are the selections for the parameter.
Selection number Selection name Selection description
0 Coast Leaves the motor in free mode
1 DC Hold/Motor Preheat Energizes the motor with a DC-hold current (see P 5.7.6 DC Hold
Current %).
Danfoss A/S © 2024.03 AB413939445838en-000301 / 130R1254 | 169