Default value: 0 [Do not reset] Parameter type: Selection
Parameter
number:
1506 Unit: –
Data type: enum Access type: Read/Write
The following are the available selections for the parameter.
Selection number Selection name
0 Do Not Reset
1 Reset Counter
P 6.1.9 Reset Running Hours Counter
Use this parameter to reset the Running Hours counter to zero (see P 6.1.3 Running Hours).
Default value: 0 [Do not reset] Parameter type: Selection
Parameter
number:
1507 Unit: –
Data type: enum Access type: Read/Write
The following are the selections for the parameter.
Selection number Selection name
0 Do Not Reset
1 Reset Counter
P 6.1.10 Internal Fault Reason
Use this parameter to view a description of the error. This parameter is used in combination with fault 38 Internal Fault.
Default value: 0 Parameter type: Range (-32767–32767)
Parameter
number:
1531 Unit: –
Data type: int16 Access type: Read
P 6.1.11 Fault Log: Time
Use this parameter to view the time when the logged event occurred. Time is measured in seconds from drive start-up.
Default value: 0 Parameter type: Range (0–2147483647)
Parameter
number:
1532 Unit: s
Data type: uint32 Access type: Read