VENUE Profile Guide182
To safe individual parameters or channels:
1 Place the cursor above the grid, above a parameter or chan-
nel name, or above any Channel Safe button. To be sure the
cursor is above a valid area, you should be able to see at least
one parameter name or channel name highlight.
2 Use the Arrow keys of the computer keyboard to move the
cursor right, left, up, or down to other grid points. (You can-
not navigate to parameter or channel grid icons, or to the
Channel Safe column.)
3 Press Enter to enable or disable safe status for the currently
focused grid point. Continue navigating to and toggling safe
status of other parameters and channels.
To safe a parameter across all currently displayed channel types:
Click the Parameter grid icon at the top of the appropriate
column until the triangle is white.
To safe all parameters for a particular channel:
Click the Channel grid icon in the ALL column for that chan-
nel (row).
To toggle the status of a parameter column or channel row:
Click the appropriate Parameter or Channel grid icon repeat-
edly until it displays the desired status. For more information,
see “Parameter Matrix” on page 181.
To safe all parameters across all channels and clear any current
settings:
Click the triangular icon at the top of the ALL column.
CHANNEL SAFE
To automation safe an individual channel and retain all recall safe
settings for that channel:
Click in the CHANNEL SAFE column for the desired channels.
To automation safe all parameters across all channels and retain
all current recall safe settings:
Click the CHANNEL SAFE master icon at the top of the Chan-
nel Safe column.
MIDI
To enable Recall Safe for MIDI Snapshot output:
Click the MIDI Snapshot Output Safe button, located above
the parameter matrix.
Plug-Ins
To enable Recall Safe for plug-ins:
Click the Plug-In Snapshot Safe button, located above the pa-
rameter matrix.
Matrix and PQ
Snapshots can store and recall all source assignments of each
Matrix and PQ mixer when the Matrix (Mtx) and/or PQ data
types is scoped. In addition, all User Input assignments are
stored, letting you reconfigure Matrix or PQ mixers and User
Input assignments on a per snapshot basis, if desired.
The Recall Safe tab of the Snapshots page provides three pa-
rameters for Matrix and PQ snapshot recall safe:
MIX Safes both Source and User assignments.
MIX SRC Safes only source inputs.
MIX USER Safes only user input assignments.
For a list of what can be stored and recalled in each snapshot,
see “Snapshot Data Types and Parameters” on page 196.
Using Scope Sets
Configurations of the Recall Safe page can be stored as Scope
Set settings files. Scope Sets can be previewed, recalled and
transferred just like plug-in, EQ and Dynamics settings.
To store the current Recall Safe settings as a Scope Set:
1 Configure the Recall Safe page as desired.
2 Click the Scope Sets icon (the folder icon located above and
to the right of the parameter matrix).
3 Click New.
To preview and recall a saved Scope Set:
1 From the Recall Safe page, click the Scope Set icon to display
the Scope Set window.
2 If necessary, choose the appropriate Scope Sets folder by
clicking and selecting it from the Folder selector.
You can undo or redo the last action taken in the parameter
matrix.
CHANNEL SAFE does not need to be lit in order to Recall
Safe individual parameters for that channel.
The CHANNEL SAFE column mirrors the channel automa-
tion Safe controls. For more information, see “Automation
Safing Channels” on page 183.
For more information, see “Adding MIDI Messages to Snap-
shots” on page 190.
For more information, see “Adding Plug-In Data to Snap-
shots” on page 192.