Installation
SmartDate X40 BFSE Version 1.0 Feb 2011
121/286
Binary Select
This is used when job selection is decided by an external system using the SmartDate
X40 flex/io.
Flexible Input Output (Flex/io)
Flex/io is a method of configuring the SmartDate X40 to interface with an
integrated control system
The SmartDate X40 has one configurable user input and two outputs that can be
configured using a flexible I/O map
Flex/io map configurations are stored as an XML file. A number of these files may
be stored in the SmartDate X40 file system
It is possible to select the required flex/io map file via the user interface
Standard Flex/io Configuration
Unless the SmartDate X40 has been configured to use a custom flex/io, map it
should be disabled
Incorrectly selecting the default flex/io will result in a continuous ‘busy’ signal
If a new flex/io map is selected the Controller must be power cycled before it will be
activated
There is a maximum of 2 jobs
For more detailed information about using and configuring the Flex/io, refer to the Flexible
IO User Manual.