Troubleshooting Guide
SmartDate X40 BFSE Version 1.0 Feb 2011
190/286
Calibration Failed Initial Tension (Fault 1107)
Possible Cause Action Notes
1
Ribbon Control
Sensor
Ö
Check the Ribbon Control
Sensor is working correctly.
Replace the Ribbon Control
Sensor
Ö
Observe the output of the Ribbon Control Sensor
in the Engineering/Diagnostics/Internal Menu. Use
a finger to apply pressure to the sensor and
observe the reading change.
Replacing the Ribbon Control Sensor Page 226
2 Printer
Ö
Replace the Printer PCB or
replace the Printer
Ö
Replacing the Printer PCB Page
226
Repl
acing the Printer: Refer to User Manual