EasyManua.ls Logo

Dover markem-imaje SmartDate X40 - Print Trigger Modes

Dover markem-imaje SmartDate X40
286 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation
SmartDate X40 BFSE Version 1.0 Feb 2011
127/286
Print Trigger Modes
The SmartDate X40 supports 3 different methods of initiating a print signal. It is important to
remember that for all print modes the minimum repeat distance depends on the speed of the
substrate and the image being printed.
External: This is the Printer default mode and is used when the print signal is
received from an external source
Internal: In this mode the Printer will automatically print the selected image at a pre-
defined distance without the need for an external print signal. The pre-defined
distance is set in the Fixed Spacing Distance parameter, which becomes available
when Internal Print Trigger is selected
Combined: In this mode a print sequence is started by an external trigger; the
remaining images are printed using internal triggers. When combined trigger mode is
enabled, two additional parameters are made available in the Print Initiation menu
o The Fixed Spacing Distance is the same as when using the internal print
trigger
o Fixed Space Count is used to enter the number of prints in the sequence